站内搜索
|
详细信息 Product Name: Hospital Single Channel Stackable Syringe Pump Medical Device (THR-SP180) Model NO.: THR-SP180 Disinfection: Without Disinfection Syringe Use: High Precision Experiments Needle: Without Needle Group: Adult Certification: CE, ISO13485 Feature: Reusable Application: Medical Material: Plastic Type: Syringe Cerfificate: Ce, ISO, TUV Fit Any Brands of Syringe Set: Calibrate The Syringe and Stored The Parameters Au Auto Detect Solution Volume: More Precise and Safe for Infusing Three Work Modes: Rate Model, Time Model and Body Weight Mode Total Volume Range: 0.1-1999.9ml (0.1 Ml Step) Bolus Rate: 10ml:10-300ml/H, 20ml(30ml):10-600ml/H Bolus Volume: Maximum of 25ml Delivery Method: by Air or by Sea Warranty: 18 Months OEM: Available Trademark: THR Transport Package: Standard Export Carton Packing Origin: China(Mainland) Product Description THR-SP180 Top syringe pumpFeatures:1. Compatible with syringes of any brand, 10ml~60ml.2. Automatically calibration for syringes of any brand.3. Three working modes: Rate control mode, Time control mode and Dose-Weight control mode.4. Automatically detection of syringe types and settings.5. Wide range in delivery rate settings.6.6 Hours continuous worked.7. Three levels of alarm volume: High, medium and low.8. Three levels of occlusion pressure: High, medium and low.9. KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus.PARAMETERSPECIFICATIonApplicable syringes10ml, 20ml, 30ml, 50ml, 60ml of any standardAccuracy+/- 2% with correct calibrationRate mode50ml(60ml): 0.1ml/h-1800.0ml/h (0.1ml/h step)20ml(30ml): 0.1ml/h-800.0ml/h (0.1ml/h step)10ml: 0.1ml/h-400.0ml/h (0.1ml/h step)Time ModeSOL. VOL: 0.1-999.9ml (0.1ml step)TIME: 1-1999min (1min step)Body Weight Mode:Volume: 0.1-999.9ml(0.1ml step)DRUG MASS: 0.1-999.9mg(0.1mg step)DOSE: 0.01-99.99ug/kg/min(0.01ug/kg/min step)WEIGHT: 0.1-300kg(0.1kg the least step)Total Volume Range0.1-1999.9ml (0.1 ml step)Purge Rate50ml(60ml): 1800.0ml/h,20ml(30ml): 800.0ml/h,10ml: 400.0ml/h, KVO Rate1ml/hOcclusion pressureThree level setting LOW, MEDIUM or HIGHAlarmsNear empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.Three levels of alarm volume LOW, MEDIUM or HIGHBolus Rate10ml: 10-300ml/h, 20ml(30ml): 10-600ml/h,50ml(60ml): 10-1200ml/hBolus VolumeMaximum of 25mlInterfaceRS-232Power sourceAC power supply: AC 100 to 240V ( +/-10%), 50/60Hz;Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 6 hours of continuous operation.Accessories:AC power line, Operational manualProtection ClassClass I, Type CF, IPX4Dimension / Net weight280mm*160mm*130mm , 2.5kg
|